← Back to calculator
Information guide

Power station for a refrigerator: estimate the runtime

Account for active compressor time, inverter losses and startup load before comparing battery capacities.

Outage duration and active runtime are different

A refrigerator compressor usually cycles on and off. If it runs for one third of an 8-hour outage, enter about 2.64 active hours. The duty cycle depends on room temperature, contents, door openings and the model. The 33% value below is an example, not a specification for your appliance.

Example capacity calculation

For an example 90 W compressor: 90 × 8 × 0.33 = 237.6 Wh of appliance energy. At the assumed 85% efficiency, at least 280 Wh of nominal capacity is needed. Other devices, idle consumption and your desired reserve increase the requirement. For a better estimate, measure energy with a suitable power meter over a representative period.

Capacity alone does not establish compatibility

Even with enough capacity, the inverter may not support compressor startup. Check continuous power, surge power and surge duration in both devices’ documentation. The calculator uses an example startup multiplier; for your refrigerator, add a custom appliance using manufacturer data.

Try your own scenario

Inverter refrigerator · 90 W · example load

Estimated nominal capacity at 85% efficiency: 280 Wh

Add more appliances to this calculation

How the calculation works

Appliance energy = average power × quantity × operating hours. For measured consumption, average power = Wh / measurement hours. Battery demand sums each appliance’s energy divided by its connection efficiency: AC 85%, USB-C 95%, DC 90%. These are planning assumptions, not manufacturer guarantees.

Output checks use the higher of nameplate power and measured average power. Inverter recommendations add 25% to AC load and 15% to AC startup power. Startup assumes one device starts while the others are already running. Available station energy = capacity × (current charge − reserve) / 100. Runtime assumes the scenario’s average load repeats.

Catalogue ratings are examples. Changing outage duration scales appliance hours proportionally. Battery ageing, temperature and idle consumption are not modelled separately; the user sets a discharge reserve. Charging balance is simplified and does not model charging taper. Saved setups stay in the browser. Ukrainian budgets are reference ranges; other markets use searches without currency conversion.

Reference: Virginia Tech — estimating energy use

Practical guides