Power station for a refrigerator: estimate the runtime
Account for active compressor time, inverter losses and startup load before comparing battery capacities.
Outage duration and active runtime are different
A refrigerator compressor usually cycles on and off. If it runs for one third of an 8-hour outage, enter about 2.64 active hours. The duty cycle depends on room temperature, contents, door openings and the model. The 33% value below is an example, not a specification for your appliance.
Example capacity calculation
For an example 90 W compressor: 90 × 8 × 0.33 = 237.6 Wh of appliance energy. At the assumed 85% efficiency, at least 280 Wh of nominal capacity is needed. Other devices, idle consumption and your desired reserve increase the requirement. For a better estimate, measure energy with a suitable power meter over a representative period.
Capacity alone does not establish compatibility
Even with enough capacity, the inverter may not support compressor startup. Check continuous power, surge power and surge duration in both devices’ documentation. The calculator uses an example startup multiplier; for your refrigerator, add a custom appliance using manufacturer data.