Backup power and portable power station calculator
Estimate the battery capacity you need (Wh), account for boiler or refrigerator startup loads, and explore suitable power stations or inverters.
Start with a ready-made setup
My saved setups (0/20)
Stored only in this browser. Reusing a name updates the setup. Clearing browser data also removes saved setups.
Choose an outage scenario
How many hours will the power outage last?
Your energy requirements
Includes measured consumption and AC / USB-C / DC conversion losses.
Choose your appliances
Select the devices you want to power during an outage and enter their expected operating hours
Wi-Fi router + optical network terminal (ONU)
A powered router and ONU can provide internet during an outage if the provider’s network remains operational.
Assumed efficiency: AC 85%, USB-C 95%, DC 90%. Check voltage, cable and output compatibility.
Laptop (office / work)
USB-C Power Delivery or a standard power adapter.
Assumed efficiency: AC 85%, USB-C 95%, DC 90%. Check voltage, cable and output compatibility.
LED lighting (desk lamp / strip)
Energy-efficient LED lamp or camping light.
Assumed efficiency: AC 85%, USB-C 95%, DC 90%. Check voltage, cable and output compatibility.
Smartphone charging (QC/PD)
Indicative smartphone or tablet charging load; adjust the time to your needs.
Assumed efficiency: AC 85%, USB-C 95%, DC 90%. Check voltage, cable and output compatibility.
Power bank charging (20,000 mAh)
Recharging a portable backup battery.
Inverter refrigerator
Example compressor power and startup factor. Enter active compressor hours, not simply elapsed outage time.
Refrigerator with a conventional compressor
A conventional compressor can have a large startup load; check the appliance specifications.
LED television, 43–55 inches
Smart TV for news, films and family use.
Microwave oven
Short food reheating sessions; adjust active time.
Electric kettle
Short boiling sessions can draw high power.
Espresso coffee machine
Heating element and high-pressure pump.
Washing machine (without water heating)
Example for an unheated wash cycle. Water heating can substantially increase power consumption.
Gas boiler (controls + pump)
Control board and built-in circulation pump; adjust to the boiler’s actual load.
Separate underfloor heating circulation pump
Pump circulating heating water through the home.
Submersible well pump
Pumping water from a well into a pressure tank.
Aquarium (filter + air pump)
Water filtration and aeration for fish.
Starlink V2 / V3 / Mini
Satellite internet. Consumption depends on model, weather and heating mode.
Desktop computer (tower)
Workstation for programming, video editing or design.
Additional monitor, 27–32 inches
A second screen for work.
CPAP device / nebuliser
Example load only. Confirm backup power requirements with the device manufacturer and care provider.
My station: how long will it last?
Initial values are examples. Replace them with your station’s specifications. Enter USB-C/DC limits for simultaneous use; also check the manufacturer’s total output limit.
Energy after charge level and reserve: 921.6 Wh
Estimated runtime: 7 h 28 min
Enough energy for the selected scenario.
Runtime assumes the selected scenario’s average load repeats.
Will it recharge between outages?
This model routes the load through the battery. For bypass, enter 0 here and use the actual available charging power. Charging taper, temperature and BMS limits may increase charging time.
The energy balance supports repeated cycles.
Recover used energy: 1 h 6 min · From current to full charge: 0 min
| Cycle | Before outage | Outage shortfall | After charging | Charging-period shortfall |
|---|---|---|---|---|
| 1 | 921.6 Wh | 0 Wh | 921.6 Wh | 0 Wh |
| 2 | 921.6 Wh | 0 Wh | 921.6 Wh | 0 Wh |
| 3 | 921.6 Wh | 0 Wh | 921.6 Wh | 0 Wh |
| 4 | 921.6 Wh | 0 Wh | 921.6 Wh | 0 Wh |
| 5 | 921.6 Wh | 0 Wh | 921.6 Wh | 0 Wh |
| 6 | 921.6 Wh | 0 Wh | 921.6 Wh | 0 Wh |
Compare up to three stations
All stations use the same appliance setup. Enter specifications from their documentation.
| Station | Runtime | Energy / outputs | Energy recovery |
|---|---|---|---|
| Station 1 | 7 h 28 min | ✓ / ✓ | 1 h 6 min |
Battery saving plan
Each suggestion is compared with your current setup independently. Runtime gains cannot be added together.
Compatible direct connection: Laptop (office / work)
−32.2 Wh · +31 min
Compatible direct connection: Smartphone charging (QC/PD)
−7.43 Wh · +7 min
Halve operating time: Laptop (office / work)
−152.94 Wh · +3 h 21 min
Halve operating time: Wi-Fi router + optical network terminal (ONU)
−35.29 Wh · +34 min
Turn off appliance: Laptop (office / work)
−305.88 Wh · +12 h 7 min
Turn off appliance: Wi-Fi router + optical network terminal (ONU)
−70.59 Wh · +1 h 15 min
Result image
PNG with appliances, station parameters and the full link. A QR code is included when the link fits.
Country of purchase
Determines stores and search language. Interface language does not change your selected market.
Equipment requirements and store searches
Review the technical requirements and search offers in your selected country.
Equipment requirements summary
Assumed efficiency depends on connection: AC 85%, USB-C 95%, DC 90%. Zero AC power means selected devices use direct outputs; check their limits.
- Output waveform: check pure sine wave compatibility for motors, controls and pumps.
- Battery chemistry: consider LiFePO4 for frequent cycling; check the exact model’s cycle rating and warranty.
- Mains charging: verify the battery can recover the energy used within your available charging window.
- Compatible DC or USB-C PD outputs can power routers and laptops without running the AC inverter.
- Overload and short-circuit protection.
Country of purchase: Ukraine
Find current models and prices
Search terms use the market language. Verify that the returned offers meet your requirements.
Backup power options
Portable power station (plug and play)
Portable all-in-one unit with AC sockets, USB and a display
Best suited to: Flats, rented homes and quick setup without rewiring
Reference range; verify with the seller.
Advantages:
- • Ready to power compatible appliances directly
- • Portable: move between rooms or take with you
- • No fuel exhaust; fan noise varies by model
Limitations:
- • Often costs more per kWh than a stationary system
- • Appliances may need manual reconnection; never use a male-to-male cable
Stationary inverter system (24/48 V inverter + LiFePO4)
Backup supply connected through a home distribution board
Best suited to: Owner-occupied flats and houses that need automatic backup for selected circuits
Reference range; verify with the seller.
Advantages:
- • May offer a lower cost per Wh at higher capacities
- • Automatic transfer where supported; check transfer time for sensitive devices
- • Scalable power and battery capacity within system limits
Limitations:
- • Requires an electrician and distribution board work
- • Heavy equipment; not intended to be moved regularly
Frequently asked questions and practical advice
Connection safety, boiler compatibility, LiFePO4 batteries and startup loads
Practical guides
Power station for a refrigerator: estimate the runtime
Account for active compressor time, inverter losses and startup load before comparing battery capacities.
Read guideGas boiler backup power: output and battery capacity
Estimate the energy needed for controls and a pump, and learn which compatibility checks need separate attention.
Read guideInternet during an outage: power for a router and ONU
Calculate both devices’ consumption, compare capacity in Wh and check whether the provider’s network stays online.
Read guideHow the calculation works
Appliance energy = average power × quantity × operating hours. For measured consumption, average power = Wh / measurement hours. Battery demand sums each appliance’s energy divided by its connection efficiency: AC 85%, USB-C 95%, DC 90%. These are planning assumptions, not manufacturer guarantees.
Output checks use the higher of nameplate power and measured average power. Inverter recommendations add 25% to AC load and 15% to AC startup power. Startup assumes one device starts while the others are already running. Available station energy = capacity × (current charge − reserve) / 100. Runtime assumes the scenario’s average load repeats.
Catalogue ratings are examples. Changing outage duration scales appliance hours proportionally. Battery ageing, temperature and idle consumption are not modelled separately; the user sets a discharge reserve. Charging balance is simplified and does not model charging taper. Saved setups stay in the browser. Ukrainian budgets are reference ranges; other markets use searches without currency conversion.
Reference: Virginia Tech — estimating energy use